[Beowulf] Clos networking and myrinet
Many of your questions may have already been answered in earlier discussions or in the FAQ. The search results page will indicate current discussions as well as past list serves, articles, and papers.
Mack.Joseph at epamail.epa.gov Mack.Joseph at epamail.epa.govWed Jun 8 12:10:10 PDT 2005
- Previous message: [Beowulf] Clos networking and myrinet
- Next message: [Beowulf] Clos networking and myrinet
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Joseph Mack PhD, High Performance Computing & Scientific Visualisation LMIT, Supporting the EPA Research Triangle Park, NC 919-541-0007 Federal Infrastructure Contact-Ravi Nair 919-541-5467 - nair.ravi at epa.gov, Federal Visualization Contact - Joe Retzer, Ph.D. 919-541-4190 - retzer.joseph at epa.gov beowulf-bounces at beowulf.org wrote on 06/08/2005 02:02:40 PM: > On Tue, Jun 07, 2005 at 11:33:06AM -0400, Mack. > Joseph at epamail.epa.gov wrote: > > > >From other reading I find that 3 layer Clos networks > > are blocking but that 5 (and above) layers are non-blocking. > > That blocking and non-blocking stuff is all a myth. Clos > networks have a special property if you are doing circuit > switching, like is done in the telecom market: Node A > talks to Node B and only node B. With a Clos network, > you have a dedicated path from A to B for > every node on the network. > > In a Linux cluster, each node talks to multiple other nodes. So they > always interfere with each other. will have to think about this. Is this true for 5, 7 ... n layer Clos networks too? Since I don't understand what's going on here, I'll try a few questions o If all nodes in a beowulf were exchanging data in pairs before a barrier and then later were exchanging data in a different combination of pairs before another barrier, which pairwise exchanges would be blocked? o Is a Clos network ever non-blocked? o Why does myrinet use Clos switching for beowulfs, if block/non-blocking isn't an issue? > > With large beowulfs, why is the diameter of the network > > increased from 3 to 5 to 7...? > > Because the maximum number of nodes you can support with > only 3 layers is limited by the size of the switch chips > you're using. Got it (I was expecting something much more complicated). Thanks Joe
- Previous message: [Beowulf] Clos networking and myrinet
- Next message: [Beowulf] Clos networking and myrinet
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list
