[Beowulf] harmonic mitigators vs PFC?
Many of your questions may have already been answered in earlier discussions or in the FAQ. The search results page will indicate current discussions as well as past list serves, articles, and papers.
Jim Lux james.p.lux at jpl.nasa.govMon May 24 07:13:59 PDT 2004
- Previous message: [Beowulf] Correct Units for quoting Interconnect Bandwidth ?
- Next message: [Beowulf] harmonic mitigators vs PFC?
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
----- Original Message ----- From: "Mark Hahn" <hahn at physics.mcmaster.ca> To: <beowulf at beowulf.org> Sent: Sunday, May 23, 2004 10:40 AM Subject: [Beowulf] harmonic mitigators vs PFC? > Hi all. > we're doing a new machineroom, which will dissipate around 250 KW. > I'm having a hard time addressing the question of whether such a load > (all modern PFC computers) needs harmonic mitigation. the electricians > all just say "your loads are nonlinear so you need HM". I can't help > think that the cost of HM hardware translates to more than a couple more nodes! > and merely because the PSU is implemented with nonlinear components doesn't > mean that the load is noisy. You mention 800 nodes, etc., So you're talking about around 0.2% of your total hardware cost? Seems like a no-brainer to go with the recommendation of the people who are concerned, if only for political reasons. > > to my thinking, the active PFC found in current computers means precisely > that HM is not necessary, since a PFC of .97 (so says my KillAWatt) indicates > that only 3% of the power is drawn outside the ideal sine envelope. > further, we're talking about O(800) seperate power supplies, and their > harmonics are probably not perfectly synchronized, and so sub-additive. Actually, the mechanism is such that the harmonics ARE synchronized. It's not the harmonics of the switching element, it's the harmonics of the non-sinusoidal line current being drawn by a diode feeding a capacitor input filter, which looks very peaky, particularly at light loads. Those harmonics are multiples of the line frequency, and, since your 250 kVA load is almost certainly being fed from three phase, the neutral or circulating currents for the 3 x line frequency (called triplen) harmonics are of great concern. > > can anyone offer advice or references on this? we can apparently get a full > answer by hiring a power consultant to bring in some kind of fancy power > digitizer which will give us a plot of our load waveforms and presumably also > a spectrum. so far, we're going along with the HM plan, but mainly because > it'll clean up the power coming in, and perhaps permit us to ride out some > flickers (the compute nodes won't have UPS-protected power...) Got an oscilloscope? Just hook it up to measure the current going into one of your nodes. If it's a digitizing scope (any will do, because you're looking at lowish frequencies), grab a few cycles worth of the data, and run a transform to look at the power spectrum. Somewhere, about 3 or 4 months ago, someone posted a link to a very nice explanation of managing harmonics in this sort of situation.
- Previous message: [Beowulf] Correct Units for quoting Interconnect Bandwidth ?
- Next message: [Beowulf] harmonic mitigators vs PFC?
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the Beowulf mailing list